ACCURATE DISPLACEMENT MEASUREMENT BASED ON THE FREQUENCY VARIATION MONITORING OF ULTRASONIC SIGNALS

Ch. Papageorgiou, Th. Laopoulos
Abstract:
This paper introduces a different approach to the measurement of the time-of-flight of ultrasonic signals. Frequency variation monitoring and recording is used to determine accurately the arrival time of the ultrasonic signal. A high speed Digital Signal Processor (D.S.P.) is used for both: transmission and direct measurement of the frequency of the incoming signal in every single period and with an accuracy of about 0.1%. The proposed configuration offers small size and low cost solution to displacement measurements with a remarkable performance in terms of accuracy, range and measurement time.
Keywords:
ultrasonic transducers, frequency variation, displacement measurement
Download:
PWC-2003-TC14-020.pdf
DOI:
-
Event details
Event name:
XVII IMEKO World Congress
Title:

Metrology in the 3rd Millennium

Place:
Dubrovnik, CROATIA
Time: