CHARACTERIZATION OF THE PYROMETERS TO THE SUBJECT OF PREAMPLIFIER GAIN NONLINEARITY |
---|
Humbat Nasibov, Sevilay Ugur |
- Abstract:
- Dc-operated radiation thermometers, due to their high-speed response, simple and rigid optical and electrical systems are widely used in industry and science. Practically, in all metrology laboratories the realization and dissemination of the temperature scale (by means of radiation temperature) is carried out using the dc-operated transfer standard radiation thermometers. Therefore, the actuality of the accurate characterization of all aspects of the pyrometer system is evidently clear.
This paper describes the systematic error contribution of the gain non-linearity of well-designed preamplifiers in the signal processing of the dc-operated radiation thermometers. - Keywords:
- radiation thermometer, preamplifier gain nonlinearity, noise equivalent temperature
- Download:
- PWC-2003-TC12-028.pdf
- DOI:
- -
- Event details
- Event name:
- XVII IMEKO World Congress
- Title:
Metrology in the 3rd Millennium
- Place:
- Dubrovnik, CROATIA
- Time:
- 22 June 2003 - 28 June 2003