APPLICATION OF SELF-CALIBRATING THERMOCOUPLES WITH MINIATURE FIXED-POINT CELLS IN A TEMPERATURE RANGE FROM 500°C TO 650°C IN STEAM GENERATORS

Frank Bernhard, Dirk Boguhn, Silke Augustin, Helge Mammen, Andrej Donin
Abstract:
Using integrated miniature fixed-point cells, a measuring uncertainty of < 1 K can be reached under operating condi tions in the superheated steam range of power plants by a periodic recalibration of the thermocouples, with operating times of > 20000 h. The fixed-point materials used for a temperature range from 500°C to 650°C are technically pure metals and binary alloys.
Keywords:
temperature measurement, measuring uncertainty, self-calibration, fixed-point, superheated steam
Download:
PWC-2003-TC12-005.pdf
DOI:
-
Event details
Event name:
XVII IMEKO World Congress
Title:

Metrology in the 3rd Millennium

Place:
Dubrovnik, CROATIA
Time:
22 June 2003 - 28 June 2003