DETERMINATION OF SOUND CAUSED BY COMPRESSOR VALVES USING TIME SIGNAL ANALYSIS |
---|
Peter Kral, Harald Hackl |
- Abstract:
- The measurement of sound levels of noise sources located very closely together – for example the inlet and outlet valve of a piston compressor – is a difficult task. This paper describes a method to evaluate the emitted noise levels of each valve. To achieve precise results, an analysis of the sound pressure level depending on time (time-signal) was done. Signal processing and computations of the measurement results lead to clearer separation of the sound emitted by each sound source (valve).
- Keywords:
- noise measurement, time signal, sound intensity
- Download:
- PWC-2003-TC4-092.pdf
- DOI:
- -
- Event details
- Event name:
- XVII IMEKO World Congress
- Title:
Metrology in the 3rd Millennium
- Place:
- Dubrovnik, CROATIA
- Time: