FAST TESTING OF ADC USING UNIFIED ERROR MODEL |
---|
Linus Michaeli, Peter Michalko, Ján Šaliga |
- Abstract:
- The progress in the technology of the analogue to digital converters (ADCs) suppresses the error effects linked with its inherent architecture. Multiperiodicity of differential nonlinearity and the impact of analog components at the ADC input on the integral nonlinearity prefers unified behavioural error model expressed as one dimensional image in the code k domain. The paper presents two new methods for low code frequency testing. The first one is based on synchronous detection of higher harmonics in ADC output record. Second apply repetitive best fitting method to estimate the harmonics. detection by multiplone utilise combination of the fast. testing methods, which allow to identify the model parameters. The high code frequency model component could be determined by fast histogram method using reduced FS triangular voltage.
- Keywords:
- ADC Modelling, ADC Testing
- Download:
- PWC-2003-TC4-023.pdf
- DOI:
- -
- Event details
- Event name:
- XVII IMEKO World Congress
- Title:
Metrology in the 3rd Millennium
- Place:
- Dubrovnik, CROATIA
- Time:
- 22 June 2003 - 28 June 2003